Description
Areometers for milk
Density reading range kg/m³ 1020-1040
Scale value, kg/m³: 0.5
Length, mm: 350
Areometers for milk with thermometer
Density reading range kg/m³: 1015 - 1040
Scale value, kg/m³: 1
Scale value temperature °C: 1
Temperature range, °C 0 +35
Length, mm: 330
Areometers for alcohol АSP-1; АSP-2; АSP-3
Scale interval, % - 0,1 (for ASP-1, ASP-2); 1 (for ASP-3)
Measuring range of volume fraction, % - 0 - 105 (with 10 steps for ASP-1)
11 - 96 (with ASP-2 in 5 steps)
0 - 100 (in increments of 30 for ASP-3)
Areometers for alcohol with thermometer
Temperature range, °C -25 +35
Scale interval, °С: 1
Length, mm: 380
Scale scale interval, %: 1
Measuring range of volume fraction, % 0 - 60; 60 - 100
Areometers for sugar АS-2, АS-3
Scale interval of mass fraction, %: 0,2 (for АS-2); 0,5 (for АS-3)
Measurement range of mass fraction, % - 0 - 20 (for AS-2 in 10 steps) - 0-75 (for AS-3 in 25 steps).
Areometers for sugar with thermometer АSТ-1; АSТ-2
Scale scale interval temperature °С: 1
Temperature range, °С From: 0 +40
Depth of scale value of mass fraction, % - 0,05 (for AST-1); 0,1 (for AST-2)
Measuring range of mass fraction, % - 0 - 24 (in steps 8 for AST-1); 5 to 30 and 10 to 70 (for AST-2)
Areometers for petroleum products AH
Density measuring range kg/m3 - 650 to 1070 (in increments of 30)
Areometers for oil products with thermometer ANT-1; ANT-2
Scale scale interval temperature °С: 1
Temperature range, °C From: -20
Scale value kg/m³ - 0,5 (for ANT-1); 1 (for ANT-2)
Measuring range, kg/m³ - 650 - 1070 (in increments of 60 for ANT-1)
670 - 1070 (in increments of 80 for ANT-2)
Areometers with thermometer AEG
Measuring range of volume fraction, % 20 - 100
Scale interval of volume fraction, %: 2
Temperature range, °С From: -20 +40
Scale scale interval, °С: 2
Length, mm: 270
Areometers for acids AK-1, AK-2
Scale interval, kg/m³ - 0,2 for AK-1; 1 for AK-2
Density measuring range, kg/m³ - 1560 - 1620 (in increments of 20 for AK-1)
1530 - 1630 (in increments of 100 for AK-2)
Areometers for soil AG
Density measuring range kg/m³ 995 - 1030
Scale interval, %: 1
Areometers for urine AU
Density reading range kg/m³ 1000 - 1050
Scale value, kg/m³: 1
Length, mm: 160
Areometers for electrolyte AE
Scale value,kg/m³: 10
Length, mm: 115
Density reading range kg/m³ - 1100 - 1400 (in steps of 200).
AON-1, AON-2, AON-3, AON-4, AON-5 general purpose areometers.
Depth values in kg/m³ - 1 (for AON-1, AON-2); 10, 20 (for AON-3); 5,10,20 (for AON-4); 0,5 (for AON-5).
Density meter range, kg/m³ - 700 - 1840 (for AON-1 in increments of 60)
1160 - 1840 (for AON-2 in increments of 80)
1000 - 1800 (for AON-3 in increments of 500)
700 to 1800 (for AON-4 in increments of 300 and 500)
650 to 1840 (for AON-5 in increments of 70)