en Caret down
Contacts: Phone icon +380679996889 sss-labor@ukr.net

Automatic Digital Refractometer ATAGO

Tubes

Description

RX-5000 Automatic Digital Refractometer ATAGO


The RX-5000 combines water bath guide tubes instead of the built-in thermomodule.

The RX-5000 is equipped with all the standard features found in the RX-α series.

It is backed by a two (2) year limited warranty from the date of original purchase. The warranty period can be extended to three (3) years if the product is registered.

Model RX-5000

Measuring range Refractive index (nD) : 1.32700 to 1.58000

Brix : 0.00 to 100.00%

Discontinuity Index of refraction (nD) : 0.00001% Brix : 0.01%

Brix : 0.01%

Accuracy of measurement

Index of refraction (nD) : ±0.00004

Brix : ±0.03%

Measuring temperature 5.00 °C to 60.00 °C

Ambient temperature 5.00 °C to 40.00 °C

Power Supply Adapter AC 100V to 240V, 50/60Hz

Power Consumption 30BA

Dimensions & Weights 37×26×14 cm, 6.4 kg (Main Unit)

Data Output Devices

Print output (Optional DP-RX digital printer)

Computer

Warranty Standard: 2 years; 3 years with product registration.

Optional accessories

DP-RX digital printer

DP-RD digital printer

10% sucrose solution for high accuracy (±0.01%)

20% sucrose solution for high accuracy (±0.01%)

30% Liquid sucrose for high accuracy (±0.01%)

40% High-precision sucrose solution (±0.02%)

50% Sucrose solution for high accuracy (±0.02%)

Parts

Cover for RX-5000

Ring

Printer paper (plain) DP-62α,DP-RX

Printer Paper (Continuous Storage) DP-62α,DP-RX

Printer paper (plain) DP-RD

Printer Ribbon Cartridge DP-RD


ATAGO RX-007α Automatic Digital Refractometer


The new RX-007α (alpha) refractometer is suitable for measuring water-soluble samples with very low concentrations (5,000% or less), such as tea (green tea, black tea, oolong tea) and low-calorie drinks with a very high accuracy of ± 0.005%.

A limited warranty of two (2) years from the date of original purchase is provided. The warranty period may be extended to three (3) years if the product is registered.

Model RX-007α

Cat.No. 3921

Measuring range

Brix 0.000 to 5.000%

Index of Refraction (RI) : 1.330150 to 1.341500

Discreteness

Brix: 0.001%

Index of refraction (RI) : 0.000001

Temperature : 0.01°C

Accuracy of measurement

Brix ± 0.005%

Index of refraction (RI) : ±0.000010 (At 20 °C)

Measuring temperature 15.00 °C to 30.00 °C

Power Supply AC 100V to 240V, 50/60Hz Adapter

Power Consumption 65BA

Dimensions & Weights 37×26×14 cm, 6.7 kg (Main Unit)

Data Output Devices

Printer (for ATAGO digital printers)

PC data output: RS-232C

When using with USB port, RS-232C / USB conversion cable must be connected.

Optional equipment

DP-RX digital printer

DP-RD digital printer

0.25% solution of sucrose (±0.005%)

0.50% sucrose solution (±0.005%)

1.00% sucrose solution (±0.005%)

Supplemental sucrose solution 5 ml 2.000% or less (± 0.005%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cassette


RX-9000α Automatic Digital Refractometer ATAGO


The RX-9000α is a fully automatic digital refractometer with the highest level of accuracy.

Designed with a wide measuring range, temperature measuring range and maximum measuring accuracy.

The instrument is suitable for measuring several types of samples, such as oils and fats with high melting point, aromatic oils with high refractive index and organic solvents, which meet the requirements of high precision measurements.

The RX-9000α has a built-in Peltier thermomodule (Peltier) to maintain a constant sample temperature during measurements. Manual calibration also allows you to adjust fluid standard values and correct for variations in measurement values between instruments.

A two (2) year limited warranty is provided from the date of original purchase. The warranty period can be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11 compliance.

Model RX-9000α

Measuring range Refractive index (nD) 1.32500 to 1.70000

Brix : 0.0 to 100.0% (ATK)

Discreteness

Index of refraction (nD) : 0.00001 or 0.0001 (option)

Brix : 0.01% or 0.1% (optional)

Temperature: 0.01 °C

Accuracy of measurement

Index of refraction (nD) : ±0.00004

(nD 1.33299 to 1.42009 at the measuring temperature

10.00 to 30.00 °C) Refractive index (nD) : ±0.00010 (in other ranges)

Brix ±0.03%

(Brix 0.00 to 50.00% at a measuring temperature of 10.00 to 30.00 °C)

Brix ±0.05%

( Brix 50.01 to 95.00% at a measuring temperature of 10.00 to 30.00 °C )

Brix ±0.10%

(for other ranges than those listed above with sucrose solution in MODE 1)

Reproducibility

Index of refraction (nD) : ±0.00002

(nD 1.33299 to 1.42009 at measuring temperature

10.00 to 30.00 °C) Refractive index (nD) : ±0.00005 (in other ranges)

Brix ±0.01%

(Brix 0.00 to 50.00% at a measuring temperature of 10.00 to 30.00 °C)

Brix ±0.02%

(For other ranges than the above with sucrose solution in MODE 1)

Temperature control range 5.00 °C to 70.00 °C (Lowest ambient temperature limit: -10 °C)

Power Supply AC adapter 100V to 240V, 50/60Hz

Power Consumption 65BA

Dimensions & weights 37×26×14 cm, 6.8 kg (Main part)

MODE-1 mode:

Displays measurement value when sample reaches target temperature.

MODE-2:

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.

Data output devices

Printer (for ATAGO digital printers)

Output from PC: RS-232C

When using with USB port, connect conversion cable RS-232C / USB.

Optional equipment

DP-RX digital printer

DP-RD digital printer

MAGIC™ (metal)

MAGIC™ (rubber)

Measuring tube with funnel for RX-9000α

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Replaceable Fan Filter


ATAGO RX-7000α Automatic Digital Refractometer


The RX-7000α (alpha) is an upgraded model with a wider range of refractive index and temperature measurements than the RX-5000α (alpha). The refractometer is equipped with a thermomodule to maintain the set temperature.

This refractometer is best suited for measuring oils and fats with high melting point, perfumes with high refractive index, organic solvents, etc.

The RX-7000α (alpha) has a manual calibration facility that compensates for differences in standard liquids and measurement values of other refractometers.

A limited warranty of two (2) years from the date of original purchase is provided. The warranty period can be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11 compliance

Model RX-7000α

Measuring range

Index of refraction (nD) 1.32500 to 1.70000

Brix : 0.0 to 100.0% (ATK)

Discreteness

Index of refraction (nD) : 0.00001 (0.0001)*

Brix : 0.01% (0.1%)*

Temperature : 0.01 °C

* Factory default setting

Accuracy of measurement

Index of refraction (nD) : ±0.0001

Brix : ±0.1% Temperature : ± 0.05 ℃ * Measured with a standard sucrose solution up to 50% Brix or standard refractive index solution in MODE-1 at 20 °C

Reproducibility

Index of refraction (nD) : ±0.00005

Brix : ±0.02% * When measuring a standard sucrose solution up to 50% Brix or a standard refractive index solution in MODE-1 at 20 °C

Temperature control range 5.00 °C to 70.00 °C (Lowest ambient temperature limit: -10 °C)

AC 100V to 240V, 50/60Hz power supply

Power Consumption 65BA

Dimensions & weights 37×26×14 cm, 6.8 kg (Main part)

MODE-1 mode:

Displays measurement value when sample reaches target temperature.

MODE-2:

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.

Data output devices

Printer (for ATAGO digital printers)

Output from PC: RS-232C

When using with USB port, connect conversion cable RS-232C / USB.

Optional equipment

DP-RX digital printer

DP-RD digital printer

MAGIC™ (metal)

MAGIC™ (rubber)

Measuring tube with funnel for RX-7000α

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Replaceable fan filter


ATAGO RX-5000α-Bev Automatic Digital Refractometer

The new RX-5000α-Bev is a newly upgraded version of the RX-5000α refractometer.

The sample receiver has been replaced by a flat design, so it is easy to clean and wipe down after measurements. The RX-5000α-Bev is designed for measuring beverages and has all the standard features of the RX-5000α.

It comes with a two (2) year limited warranty from the date of original purchase. The warranty period can be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11 compliance

Model RX-5000α-Bev

Measuring range

Index of Refraction (nD) : 1.32700 to 1.58000

Brix : 0.00 to 100.00% (ATK)

Discontinuity

Index of refraction (nD) : 0.00001

Brix : 0.01% (ATC)

Temperature : 0.01 °C

Accuracy

Index of refraction (nD) : ±0.00004

Brix : ±0.03% * When measured with a standard sucrose solution up to 50% Brix or a standard refractive index solution in MODE-1 at 20 °C

Reproducibility

Index of refraction (nD) : ±0.00002

Brix : ±0.01% * When measuring a standard sucrose solution up to 50% Brix or a standard refractive index solution in MODE-1 at 20 °C

Temperature control range 5.00 °C to 60.00 °C (Lowest ambient temperature limit: -10 °C)

AC 100V to 240V, 50/60Hz power supply

Power Consumption 65BA

Dimensions & weights 37×26×14 cm, 6.1 kg (Main part)

MODE-1 mode:

Displays measurement value when sample reaches target temperature.

MODE-2:

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.

Data output devices

Printer (for ATAGO digital printers)

Output from PC: RS-232C

When using with USB port, connect conversion cable RS-232C / USB.

Optional equipment

DP-RX digital printer

DP-RD digital printer

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Replaceable Fan Filter


ATAGO RX-5000α Automatic Digital Refractometer


The RX-5000α (α) is an automatic digital refractometer that can set the internal measurement temperature and has the following features to accurately and quickly measure the refractive index, Brix or concentration of various liquids.

Since the RX-5000α has a built-in thermomodule for temperature control, no water bath is required to maintain the temperature.

Measurement starts automatically when the target temperature is reached.

On the screen, the Brix or refractive index is displayed at the target temperature.

Values will be obtained with an accuracy of Brix ± 0.03% and refractive index ± 0.00004.

The RX-5000α displays the upper and lower values of the set reference range.

If the measurement value differs from that of your standard liquid or other refractometer, it can be adjusted within a certain range.

Depending on your sample, 60 kinds of custom scales can be entered.

The RX-5000α-Plus is capable of storing the last 30 measurements in memory.

* The special RX-5000α model allows you to pre-program an additional scale (e.g. honey moisture, inverted sugar %, salt concentration or butyrol) in addition to the refractive index and Brix (%) as desired.

A limited warranty of two (2) years from the date of original purchase is provided. The warranty period may be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11

RX-5000α



Measuring range

Index of Refraction (nD) : 1.32700 to 1.58000

Brix : 0.00 to 100.00% (ATK)

Discreteness

Index of refraction (nD) : 0.00001

Brix : 0.01% (ATC)

Temperature : 0.01 °C

Accuracy

Index of refraction (nD) : ±0.00004

Brix : ±0.03% * When measured with a standard sucrose solution up to 50% Brix or a standard refractive index solution in MODE-1 at 20 °C

Reproducibility

Index of refraction (nD) : ±0.00002

Brix : ±0.01% * When measuring a standard sucrose solution up to 50% Brix or a standard refractive index solution in MODE-1 at 20 °C

Temperature control range 5.00 °C to 60.00 °C (Lowest ambient temperature limit: -10 °C)

AC 100V to 240V, 50/60Hz power supply

Power Consumption 65BA

Dimensions & weights 37×26×14 cm, 6.4 kg (Main part)

MODE-1 mode:

Displays measurement value when sample reaches target temperature.

MODE-2:

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.

Data output devices

Printer (for ATAGO digital printers)

Data output from PC: RS-232C

When used with USB port, connect conversion cable RS-232C / USB.

Optional accessories

Digital printer DP-63

DP-AD digital printer

MAGIC™(metal)

MAGIC™ (rubber)

Measuring tube with funnel for RX-5000α-Plus

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Replaceable Fan Filter


RX-5000α-Plus ATAGO Automatic Digital Refractometer


The new RX-5000α (alpha)-Plus features improved accuracy over the RX-5000α, as Brix ± 0.010 and nD ± 0.00002.

The RX-5000α-Plus is an automatic digital refractometer that can set an internal measurement temperature and has the technical features to accurately and quickly measure refractive index, Brix or concentration of various liquids.

Because the RX-5000α-Plus has a built-in thermomodule for temperature control, no water bath is required to maintain temperature.

Measurement starts automatically when the target temperature is reached.

On the screen, the Brix or refractive index is displayed at the target temperature.

Values will be obtained with an accuracy of Brix ± 0.010% and refractive index ± 0.00002.

The RX-5000α-Plus displays the upper and lower values of the set reference range.

If the measurement value differs from that of your standard liquid or other refractometer, it can be adjusted within a certain range.

Depending on your sample, 60 kinds of custom scales can be entered.

The RX-5000α-Plus is capable of storing the last 30 measurements in memory.

This product comes standard with a two (2) year limited manufacturer's warranty against defects from the date of original purchase. The warranty period can be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11 compliance

Model RX-5000α-Plus

Cat.No. 3266

Measuring range

Index of Refraction (nD) : 1.32700 to 1.58000

Brix : 0.000 to 100.000% (at ATK)

Discreteness

Index of refraction (nD) : 0.00001

Brix : 0.005% (ATK) Temperature : 0.01 °C

Temperature : 0.01°C

Accuracy

Index of refraction (nD) : ±0.00002

Brix : ±0.010% *When measuring a standard sucrose solution up to 50% Brix or a standard refractive index solution in MODE-1 at 20 °C

Reproducibility

Refractive index (nD) : ±0.00001

Brix : ±0.010% *When measuring a standard sucrose solution up to 50% Brix or a standard refractive index solution in MODE-1 at 20 °C.

Temperature control range 5.00 °C to 60.00 °C (Lowest ambient temperature limit: -10 °C)

AC 100V to 240V, 50/60Hz power supply

Power Consumption 65BA

Dimensions & weights 37×26×14 cm, 6.4 kg (Main part)

MODE-1 mode:

Displays measurement value when sample reaches target temperature.

MODE-2:

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.

Data output devices

Printer (for ATAGO digital printers)

Output from PC: RS-232C

When using with USB port, connect conversion cable RS-232C / USB.

Optional equipment

Digital printer DP-63

DP-AD digital printer

MAGIC™(metal)

MAGIC™ (rubber)

Measuring tube with funnel for RX-5000α-Plus

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Replaceable Fan Filter


ATAGO RX-9000i Automatic Digital Refractometer


With its intuitive touch screen technology, the new RX-i series makes navigation and your choices accessible.

The RX-i series is equipped with new features such as a USB memory stick and self-diagnostic capability.

The RX-9000i is highly accurate and has a wide measurement range.

This instrument comes standard. It comes with a two (2) year limited warranty from the date of original purchase. The warranty period can be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11 compliance

Model RX-9000i

Cat.No. 3278

Measuring range

Index of Refraction (nD) : 1.32420 to 1.70000

Brix : 0.00 to 100.00% (ATK)

Discreteness

Index of refraction (nD) : 0.00001

Brix : 0.01%

Temperature : 0.01 °C

Accuracy (nD)

±0.00004 (nD 1.33299 to 1.42009, 10.00 to 30.00 °C)

±0.00010 (For ranges other than those listed above)

Brix measurement accuracy

±0.03% (Brix 0.00 to 50.00%, 10.00 to 30.00 °C)

±0.05% (Brix 50.01 to 95.00%, 10.00 to 30.00 °C)

±0.10% (For ranges other than the above with sucrose solution at MODE-1)

Reproducibility (nD)

±0.00002 (nD 1.33299 to 1.42009, 10.00 to 30.00 °C)

±0.00005 (For ranges other than those listed above)

Brix repeatability

±0.01% (Brix 0.00 to 50.00%, 10.00 to 30.00 °C)

±0.02% (For ranges other than the above with sucrose solution at MODE-1)

Temperature control range From 5.00 °C to 75.00 °C (ambient temperature must be 10 °C, not above 55 °C)

Power Supply Adapter AC 100V to 240V, 50/60Hz

Power Consumption 90BA

Dimensions & weights 37×26×14 cm, 7.0 kg (Main part)

MODE-1 mode:

Displays measurement value when sample reaches target temperature.

MODE-2:

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.

Data output devices

Printer (for ATAGO digital printers)

Computer - USB

Warranty

2 years as standard; 3 years if the device is registered.

In both cases, the touch screen of the device is not covered by the warranty.

Accessories

DP-63 Digital Printer

DP-AD digital printer

MAGIC™ (metal)

MAGIC™ (rubber)

Measuring tube with funnel

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Replaceable Fan Filter


ATAGO RX-7000i Automatic Digital Refractometer


With its intuitive touch screen technology, the new RX-i series makes navigation and your choices accessible.

The RX-i series is equipped with new features such as a USB memory stick and self-diagnostic capability.

The RX-7000i has an even wider refractive index range than its predecessor.

This instrument comes standard. It comes with a two (2) year limited warranty from the date of original purchase. The warranty period may be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11 compliance.

Model RX-7000i

Cat.No. 3279

Measuring range

Index of Refraction (nD) : 1.32420 to 1.70000

Brix : 0.00 to 100.00% (ATK)

Minimum scale value

Refractive index (nD) :0.00001 (0.0001)*

Brix : 0.01% (0.1%)*

Temperature : 0.01 °C

*Factory default setting

Accuracy of measurement

*Reproducibility

Index of refraction (nD) : ±0.0001

*±0.00005

Brix : ±0.1%

*±0.02%

[*1] When measuring a standard sucrose solution up to 50% Brix or a standard refractive index solution in MODE-1 at 20 °C.

Temperature control range

From 5.00 °C to 75.00 °C

(ambient temperature must be at least 10 °C, not over 55 °C)

Power supply AC adapter 100V to 240V, 50/60Hz

Power Consumption 90BA

Dimensions & weights 37×26×14 cm, 7.0 kg (Main part)

MODE-1 mode:

Displays measurement value when sample reaches target temperature.

MODE-2:

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.


Data Output Devices

Printer (for ATAGO digital printers)

Computer - USB

Optional accessories

Digital printer DP-63

Digital printer DP-AD

MAGIC™ (metal)

MAGIC™ (rubber)

Measuring tube with funnel

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Replaceable Fan Filter


ATAGO RX-5000i Automatic Digital Refractometer


The most accurate refractometer in the world is now even more advanced, high-tech and functional.

With intuitive touch screen technology, the new RX-i series makes navigation and your choices accessible.

The RX-5000i measures the same level of accuracy as the RX-5000α ± 0.03% Brix and ± 0.00004 nD.

The RX-i series is equipped with new features such as a USB memory stick and self-diagnostic capability.

This instrument comes standard. It comes with a two (2) year limited warranty from the date of original purchase. The warranty period may be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11 compliance.

Model RX-5000i

Cat.No. 3276

Measuring range

Index of Refraction (nD) : 1.32420 to 1.58000

Brix : 0.00 to 100.00% (ATK)

Discontinuity

Index of refraction (nD) : 0.00001

Brix : 0.01%

Temperature: 0.01 °C

Accuracy of measurement

Refractive index (nD) :±0.00004

Brix : ±0.03% * When measuring a sucrose solution (50% or less) or standard refractive index solution at MODE - 1, 20 °C

Reproducibility

Index of refraction : ±0.00002

Brix : ±0.01% * When measuring a sucrose solution (50% or less) or a standard refractive index solution at MODE of 1, 20 °C

Temperature control range From 5.00 °C to 75.00 °C (ambient temperature not below 10 °C, not above 55 °C)

Power Supply Adapter AC 100V to 240V, 50/60Hz

Power Consumption 90BA

Dimensions & weights 37×26×14 cm, 6.6 kg (Main part)

MODE-1 mode:

Displays measurement value when sample reaches target temperature.

MODE-2:

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.

Data output devices

Printer (for ATAGO digital printers)

Computer - USB

Optional accessories

Digital printer DP-63

Digital printer DP-AD

MAGIC™ (metal)

MAGIC™ (rubber)

Measuring tube with funnel

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Replaceable Fan Filter


ATAGO RX-5000i-Plus Automatic Digital Refractometer


The most accurate refractometer in the world is now even more advanced, high-tech and functional.

With intuitive touch screen technology, the new RX-i series makes navigation and your choices accessible.

The RX-5000i-Plus measures the same level of accuracy as the RX-5000α-Plus - ± 0.010% Brix and ± 0.00002 nD.

The RX-i series is equipped with new features such as a USB memory stick and self-diagnostic capability.

This instrument comes standard. It comes with a two (2) year limited warranty from the date of original purchase. The warranty period may be extended to three (3) years if the product is registered.

Included software - supports FDA 21 CFR Part 11 compliance.

Model RX-5000i-Plus

Cat.No. 3275

Measuring range

Index of Refraction (nD) : 1.32420 to 1.58000

Brix : 0.000 to 100.000% (ATK)

Discreteness

Index of refraction (nD) : 0.00001

Brix : 0.001% (ATC)

Temperature: 0.01 °C

Accuracy of measurement

Index of refraction (nD) :±0.00002

Brix : ±0.010% * When measuring a sucrose solution (50% or less) or a standard refractive index solution at MODE - 1, 20 °C

Reproducibility

Index of refraction : ±0.00001

Brix : ±0.010% * When measuring a sucrose solution (50% or less) or a standard refractive index solution at MODE of 1, 20 °C

Temperature control range From 5.00 °C to 75.00 °C (ambient temperature not below 10 °C, not above 55 °C)

Power Supply Adapter AC 100V to 240V, 50/60Hz

Power Consumption 90BA

Dimensions & Weights 37×26×14 cm, 6.6 kg (Main part)

Mode

MODE-1 (MODE-1) :

Displays the measurement value when the sample reaches the target temperature.

MODE-2 (MODE-2):

Measures refractive index and temperature at fixed intervals and displays the estimated measurement value at the target temperature.

MODE-3 (MODE-3):

The thermomodule can be turned off. Without temperature control, the measurement value is displayed 4 seconds after the START key is pressed.

MODE-S (MODE-S):

Displays the measurement value after a certain level of sample stability is reached.

MODE-T (MODE-T):

Recommended for measuring liquid samples with low Brix content (such as teas).

The RX-5000i-Plus is equipped with the MODE-T mode, recommended for users who focus on obtaining high repeatability (Brix 0.001%).

Data output devices

Printer (for ATAGO digital printers)

Computer - USB

Optional accessories

Digital printer DP-63

Digital printer DP-AD

MAGIC™ (metal)

MAGIC™ (rubber)

Measuring tube with funnel

10% sucrose solution (±0.01%)

20% sucrose solution (±0.01%)

30% sucrose solution (±0.01%)

40% sucrose solution (±0.02%)

50% sucrose solution (±0.02%)

Supplemental sucrose solution 30.00% or less (±0.01%)

Supplemental sucrose solution 30.01% to 50.00% (± 0.02%)

Ingredient parts

Printer paper (plain)

Printer paper (long life)

Printer paper (plain)

Printer ribbon cartridge

Changeable fan filter






Condition : New