Description
ATAGO PAN-1 automatic immersion refractometer (arbitrary length)
Stick length adjustable in 10 cm increments up to 120 cm.
Scale
Brix
Temperature
Adjustable length 60 cm - 120 cm (in 10 cm increments)
* Other features are common to the PAN-1.
Automatic immersion refractometer ATAGO PAN-1(L)
The PAN-1(L) is 50 cm long.
No special equipment is required to install the instrument. Simply place the instrument on the edge of a tank or reservoir.
Temperature and Brix readings are automatically updated every 30 seconds.
Measuring range
Brix from 0.0 to 42.0%
Temperature 10.0 to 99.9 °C
Minimum scale value
Brix 0.1%
Temperature 0.1 °C
Accuracy of measurement
Brix ±0.2%
Temperature ±0.5 °C
Measuring temperature 10.0 to 95.0 °C
Ambient temperature 10 to 45 °C
International protection class
Instrument part that is immersed in the sample - IP67
Display - IP65
Power supply
1× 1.5V alkaline battery
Dimensions and weight 80×72×600 mm, 730 g (main part)
Optional accessory 1.5 V alkaline dry cell battery (1 pcs.)
Automatic immersion refractometer ATAGO PAN-1(M)
The PAN-1 (M) refractometer is 30 cm long.
No special equipment is required to install the instrument. Simply place it on the edge of a tank or reservoir.
Temperature and Brix readings are automatically updated every 30 seconds.
Measuring range
Brix 0.0 to 42.0%
Temperature 10.0 to 99.9 °C
Minimum scale value
Brix 0.1%
Temperature 0.1 °C
Accuracy of measurement
Brix ±0.2%
Temperature ±0.5 °C
Measuring temperature 10.0 to 95.0 °C
Ambient temperature 10 to 45 °C
International protection class
Instrument part that is immersed in the sample - IP67
Display unit - IP65
Power supply 1 × alkaline battery 1.5 V
Dimensions and weight 80×72×400 mm 660 g (main part)
Optional accessory 1.5 V alkaline dry cell battery (1 pc.)
ATAGO PAN-1 Automatic Immersion Refractometer
No special equipment is required for setting up the instrument. Just place it on the edge of a tank or vessel.
The refractometer shows continuous real-time readings and is suitable for measuring all types of liquids, from filtration and refrigeration fluids, to food and beverages.
Temperature and Brix readings are automatically updated every 30 seconds.
Measuring range
Brix from 0.0 to 42.0%
Temperature 10.0 to 99.9 °C
Minimum scale value
Brix 0.1%
Temperature 0.1 °C
Accuracy of measurement
Brix ±0.2%
Temperature ±0.5 °C
Measuring temperature 10.0 to 95.0 °C
Ambient temperature 10 to 45 °C
International protection class
Instrument part that is immersed in the sample IP67
Display IP65
Power supply 1× 1.5 V alkaline battery
Dimensions and weight 80×72×300 mm 630 g (main part)
Supplementary equipment 1.5 V alkaline dry cell battery (1 pc.)