Automatic Hematology Analyzer 5500 5-Part-Diff

Tubes

Description

The automatic hematology analyzer -5500 5-Part-Diff performs a large volume of quantitative and qualitative blood tests. Automatically and accurately measures the concentration of hemoglobin in the blood.

The tests are performed according to the following parameters: WBC, LYM%, MON%, NEU%, EOS%, BAS%, LYM#, MON#, NEU#, EOS#, BAS#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, PCT, P_LCR, RETIC%, RETIC_ABS, IRF, ALY%, LIC%, NRDC%, ALY#, LIC#, NRBC#.

The following methods of analysis are used during measurements:

1. Electrical impedance method to determine the number and distribution of erythrocytes and platelets;

2. optical laser diffraction method for differentiating leukocytes into 5 subpopulations;

3. Colorimetric method to determine the amount of hemoglobin.



Technical Characteristics

Parameters Description Deciphering
Test parameters 34 parameters and 6 charts 2 scatter plots, 2 histograms, 2 3D graphs
Sample Opened vials Blood volume 100 µl
Visualization Equipped with a computer Convenient data management and network setup
Data storage ≥ 200,000 exam results (with graphs). Unlimited data storage possible by expanding PC memory.
Speed Single (ad hoc) sampling - 100 tests/hour

Continuous Sample Collection - 110 tests/hour
Output mode External printer, histogram print selection Reference range can be printed in report format
Blood volume 100 µl Anticoagulant EDTA-K2/EDTA-K3
Reagents Diluent, Detgent, Lytic Reagent, Covering Reagent
Monitoring and calibration With calibrator, automatic and manual calibration; LJ, X, XR, XB, etc.
Coefficient of variation WBC : ≤1.5%
RBC : ≤1.0%
HGB : ≤1.5%                        Linearity
MCV : ≤1.0%
HCT : ≤2.0%
PLT : ≤4.0%
WBC:0.0×109/L-99.9×109/L
RBC:0.1×1012/L-7.00×1012/L
HGB: 0 g/L-300g/L
PLT:0×109/L-999×109/L
Service Automatic device condition monitoring function Enhance the life of the instrument, keep the instrument in better condition
Patient Parameters 9 different normal range parameter groups Can be adjusted according to different geographical groups; the instrument will automatically identify and display the correct values
Flushing High voltage cauterization . The replaceable ruby aperture plate is easy to clean. Positive and negative recoil pressure and intelligent automatic cleaning
Power safety Powerful voltage regulating unit required
Size 760MM×684MM×676.5MM (length × width × height)
Voltage ≤600VA
Fuse 250V/2.5A
Weight Approximately 91.5 kg