Description
The automatic hematology analyzer -5500 5-Part-Diff performs a large volume of quantitative and qualitative blood tests. Automatically and accurately measures the concentration of hemoglobin in the blood.
The tests are performed according to the following parameters: WBC, LYM%, MON%, NEU%, EOS%, BAS%, LYM#, MON#, NEU#, EOS#, BAS#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, PCT, P_LCR, RETIC%, RETIC_ABS, IRF, ALY%, LIC%, NRDC%, ALY#, LIC#, NRBC#.
The following methods of analysis are used during measurements:
1. Electrical impedance method to determine the number and distribution of erythrocytes and platelets;
2. optical laser diffraction method for differentiating leukocytes into 5 subpopulations;
3. Colorimetric method to determine the amount of hemoglobin.
Technical Characteristics
| Parameters | Description | Deciphering |
| Test parameters | 34 parameters and 6 charts | 2 scatter plots, 2 histograms, 2 3D graphs |
| Sample | Opened vials | Blood volume 100 µl |
| Visualization | Equipped with a computer | Convenient data management and network setup |
| Data storage | ≥ 200,000 exam results (with graphs). Unlimited data storage possible by expanding PC memory. | |
| Speed | Single (ad hoc) sampling - 100 tests/hour Continuous Sample Collection - 110 tests/hour |
|
| Output mode | External printer, histogram print selection | Reference range can be printed in report format |
| Blood volume | 100 µl | Anticoagulant EDTA-K2/EDTA-K3 |
| Reagents | Diluent, Detgent, Lytic Reagent, Covering Reagent | |
| Monitoring and calibration | With calibrator, automatic and manual calibration; LJ, X, XR, XB, etc. | |
| Coefficient of variation | WBC : ≤1.5% RBC : ≤1.0% HGB : ≤1.5% Linearity MCV : ≤1.0% HCT : ≤2.0% PLT : ≤4.0% |
WBC:0.0×109/L-99.9×109/L RBC:0.1×1012/L-7.00×1012/L HGB: 0 g/L-300g/L PLT:0×109/L-999×109/L |
| Service | Automatic device condition monitoring function | Enhance the life of the instrument, keep the instrument in better condition |
| Patient Parameters | 9 different normal range parameter groups | Can be adjusted according to different geographical groups; the instrument will automatically identify and display the correct values |
| Flushing | High voltage cauterization . The replaceable ruby aperture plate is easy to clean. Positive and negative recoil pressure and intelligent automatic cleaning | |
| Power safety | Powerful voltage regulating unit required | |
| Size | 760MM×684MM×676.5MM (length × width × height) | |
| Voltage | ≤600VA | |
| Fuse | 250V/2.5A | |
| Weight | Approximately 91.5 kg | |