en Caret down
Contacts: Phone icon +380679996889 sss-labor@ukr.net

Automated ELISA Analyzer ThunderBolt 2 Plate Analyzer

Tubes

Description

Intelligent tripods provide automatic sample location recognition.

- System customizable to user requirements.

- High precision sampler system for aspirating sample/reagent volume from 1 µl with highest precision - < 3% CV.

- Built-in, compact ELISA reader.

- Incubator with uniform and identical heating of all cells: uniform heating and no "Edge Effect" is ensured by an equal number of resistors around each cell as well as by external air supply via fixed tubing.

- An integrated camera on-board the instrument, attached to the sampler system, is designed to monitor the process inside the instrument in "real time" and to troubleshoot problems remotely.

- A sliding rack holder for samples and reagents allows easy loading and unloading of samples and reagents.

- Built-in barcode reader to optimize loading and reduce the likelihood of errors.

- Orbital microplate shaker on board instrument, no contamination even at high rpm.

- The smallest automated ELISA instrument on the market, will save workspace in the lab.

Specifications

- Capacity: up to 192 samples (including controls and calibrators) loaded simultaneously

- 16 reagent positions. Adapters for different sized vials are included to avoid transferring reagents from one vial to another.

- Specimen racks are designed for standard sizes of tubes used in the lab: 12, 13 and 16 mm in diameter. If smaller tubes are required, adapters can be used.

To optimize work it is also possible to include in the set of racks designed for the size of vials of ELISA reagent manufacturers, for example, vials of controls and calibrators from reagent kits of IBL International (Tecan Group).

- 2 Positions for ELISA microplate

- Each cell in the microplate is a separate ELISA process, allowing flexibility in programming the instrument and tracking results.

- Possibility to perform several tests simultaneously (in case of similar protocols).

- The instrument can be integrated into the LIS laboratory.

- 2 vials for flushing buffer outside the instrument.

High precision sampler system with 2 needles (2in1): one for dispersion and one for aspiration.

Very low dead volume when taking samples/reagents. Low sample/reagent volume alarm

Low sample/reagent volume alarm.

- Dispensing volume up to 300µl.

- Aspiration volume from 1µl.

- Incubation temperature up to 40ºC.

- Standard built-in spectrophotometer wavelengths used in ELISA diagnostics: 405, 450, 490, 550 and 630 nm.

- Orbital microplate shaker for ELISA: amplitude: 1mm; speed: up to 900 rpm; capacity: 3 microplates (2 basic and 1 for pre-dilution).

- Power supply: 120-265 V, 50-60 Hz.

- Dimensions: W: 64 cm, L: 57 cm, H: 45 cm.

- CE Certificate.

Software

- Supports several languages.

- Calculation of results: by points, linear regression, cubic spline, 4PL, 5 PL, Lin-Lin, Lin-Log, Log-Log representation.

- Fully customizable software architecture.

- Flexible test developer; customizable results report.

- LIS integration capability.

- Bidirectional, RS232, USB, TCP/IP.

- User interface: MS Windows graphical user interface (Windows 7, Windows 8).

Unique features:

-Intelligent tray

-Automated sample positioning control.

-Open system architecture.

-High precision microsyringe Aspiration of 1 µl with ≤ 3% CV.

-Built-in reader (spectrophotometer) Spectrophotometer or Spectrophotometer + Fluorescence combo reader Forced convection incubator Heats the surface evenly with forced air circulation to eliminate the edge effect.

-Built-in video camera

-Video camera allows remote troubleshooting.

-Pull-out sample tray

-Easy to load and unload samples.

-Built-in barcode reader to streamline loads and reduce errors

-Sample tracking.

-Orbital MTP shaker

-Accurate adherence to analysis protocols.